Depth of discharge (DoD) and battery lifetime
Understand what DoD is, why shallower discharges give more cycles and how much energy a battery delivers over its life, and try the values in the calculator.
What depth of discharge is
The depth of discharge (DoD) says how much of the battery’s capacity you use in one cycle. If a 10 kWh battery delivers 8 kWh before being recharged, the discharge was 80%.
Why shallow discharges last longer
Each cycle wears the battery, and wears it more when it is deeper. The number of cycles a battery can take falls sharply with the depth of discharge, and the drop is steeper for lead-acid.
Calculate your battery’s life
Choose the type, the discharge of each cycle and the nominal capacity. The calculator interpolates the table and shows the cycles, the years (at one cycle per day) and the total energy the battery delivers over its life.
More cycles is not always more energy
Shallow discharges give more cycles, but each cycle delivers less energy. What matters is the total energy delivered over its life (capacity × DoD × cycles, an idealized estimate that ignores capacity loss over its life). For a 5 kWh lithium battery:
In the illustrative table used here, the range between 50% and 80% delivers the most accumulated energy. Raising the depth of discharge to 100% reduces total energy. In this example, operating at 30% DoD also reduces the calculated accumulated energy; the real choice also depends on the reserve you want and the operating conditions.
Using DoD in sizing
- 1Set the energy per day
The home needs 5 kWh from the battery per day.
- 2Choose the design DoD
With lithium at 80%, the nominal capacity is 5 ÷ 0.8 = 6.25 kWh. At 50% it would be 10 kWh.
- 3Estimate the life
At 80% that is 4,000 cycles: at one cycle per day, about 11 years (arithmetic equivalent at one cycle per day, ignoring calendar ageing) and 20,000 kWh delivered, as an idealized estimate.
Do
- Set the discharge cut-off on the inverter to match the chosen DoD
- Use the manufacturer’s datasheet, which gives the cycles per DoD
- Remember that life also depends on temperature and current
- Leave a reserve for autonomy: see how to calculate backup time
Avoid
- Discharge to zero often
- Leave the battery discharged for long periods
- Compare batteries by nominal capacity alone
- Buy extra capacity that will never be used
Draw it in Editor Solar
This is Editor Solar itself, already loaded with the diagram from this article. Move the equipment, edit labels, connect new parts and export to PNG, SVG or PDF. It is free and runs right in your browser.
Try it: Change the DoD to 50% and redo the bank’s nominal capacity. Note how many extra kWh you would need to buy.
Ready-made templates: see all diagram templates